GC
The implementation described in this PICS proforma meets all of the mandatory requirements of the referenced standards
M
true
ZDD
Zigbee Direct Device. Does the implementation support a Zigbee Direct Device?
O.1
X
true
ZVDCC
Zigbee Direct Commissioning Component. Does the implementation consist of a Zigbee Direct Commissioning Component?
O.1
X
false
ZVDSC
Zigbee Stack Component. Does the implementation consist of a Zigbee Stack Component?
O.1
X
false
ZVDZCL
ZCL Component. Does the implementation consist of a ZCL Component?
O.1
X
false
ZVDBDB
BDB Component. Does the implementation consist of a BDB Component?
O.1
X
false
ZDZVD-C
Commissioning ZVD Component. Does the implementation consist of Commissioning ZVD Component?
O.1
X
false
ZDZVD-F
ZVD-TS Component. Does the implementation consist of a ZVD-TS Component?
O.1
X
false
The implementation MUST indicate YES to one, and only one, from the list above.
ZVDSC-I
Zigbee Stack Component build on an eligible Zigbee PRO stack with existing ZCP certification
O.2
X
false
ZVDSC-N
New Zigbee Stack Component
O.2
X
false
In case the implementation is a Zigbee Stack Component (ZVDSC) the implementation MUST indicate YES to one, and only one, from the list above.
ZVDSC-22
Zigbee Stack Version. Is the implementation based on revision 22 of the Zigbee PRO specification?
O.1
X
false
In case the implementation is a Zigbee Stack Component (ZVDSC) the implementation MUST
indicate YES or NO to the item.
BLER
The implementation described in this PICS proforma is either directly or via stated dependencies build upon a BLE interface with the functionality defined in section 7.4 of [R1].
M
true
ZVDC1
Top Level Component type 1. Does the implementation consist of a TLC of type 1?
O.4
X
X
O
false
ZVDC2
Top Level Component type 2. Does the implementation consist of a TLC of type 2?
O.4
X
X
O
false
ZVDCC
Component. Does the implementation consist of a (non-top-level) component?
O.4
X
M
X
O
false
The implementation MUST indicate YES to one, and only one, from the list above in case the Zigbee Direct Device or Component Type is not ZDD.
ZC
Zigbee Coordinator Device Type
O.5
X
false
ZR
Zigbee Router Device Type
O.5
X
false
ZED
Zigbee End Device Device Type
O.5
X
false
The implementation MUST indicate YES to at least one, and MAY also indicate YES to multiple items in case the Zigbee direct Device Type is ZDD or ZDZVD-F.
ZDCS
Zigbee Direct Commissioning Service. Does the implementation support all Zigbee Direct Commissioning Service characteristics?
M
true
ZVDCCL
Zigbee Direct Commissioning Client. Does the implementation support writing BLE GATT attributes of the Zigbee Direct Commissioning Service?
M
false
ZDTS
Zigbee Direct Tunneling Service. Does the implementation support the Zigbee Direct Tunneling GATT Service?
O
true
ZDTC
Zigbee Direct Tunneling Client. Does the implementation support writing Tunneling Service characteristics in order to tunnel Zigbee messages?
X
M
false
CRYPTO1
Crypto Option 1. Does the device support authentication using ECDHE-PSK/P-256/SHA-256/HMAC-SHA-256-128?
O.6
true
CRYPTO2
Crypto Option 2. Does the device support authentication using SPEKE/Curve25519/AES-MMO-128/HMAC-AES-MMO-128?
O.6
true
The ZDD MUST select at least one of the two options, but may select both.
ZBCMJ
Zigbee Direct Manage Joiners. Does the device support Manage Joiners commands using Manage Joiners commissioning characteristic?
O
O
true
ZBCFB
Zigbee Direct Finding&Binding. Does the device support Finding&Binding commands using Finding&Binding commissioning characteristic?
O
O
true
ZBCID
Zigbee Direct Identify. Does the device support the Identify commands using the Identify commissioning characteristic ?
M
O
true