<?xml version="1.0" encoding="UTF-8"?>
<homeAutomationPICs version="">
	<implementationIdentification>
		<IUTIdentification>
			<description>Implemenation Under Test Identification</description>
			<UITName mandatory="true">GWA1521_Actuator_1_CH</UITName>
			<UITVersion mandatory="true">1</UITVersion>
		</IUTIdentification>
		<SUTIdentification>
			<description>System Under Test Identification</description>
			<SUTName>GWA1521_Actuator_1_CH</SUTName>
			<SUTSoftwareVersion mandatory="true">1</SUTSoftwareVersion>
			<SUTHardwareVersion mandatory="true">1</SUTHardwareVersion>
			<SUTOperatingSystem mandatory="false"/>
		</SUTIdentification>
		<productSupplier>
			<description>Product Supplier</description>
			<name>GEWISS S.p.A.</name>
			<address>Via A. Volta 1, I-24069 Cenate Sotto</address>
			<telephoneNumber>+39035946111</telephoneNumber>
			<faxNumber>+39035945270</faxNumber>
			<emailAddress>edoardo.errico@gewiss.com</emailAddress>
			<additionalInformation/>
		</productSupplier>
		<client>
			<description>Client</description>
			<name/>
			<address/>
			<telephoneNumber/>
			<faxNumber/>
			<emailAddress/>
			<additionalInformation/>
		</client>
		<picsContactPerson>
			<description>PICS Contact Person</description>
			<name>Edoardo Errico</name>
			<address/>
			<telephoneNumber/>
			<faxNumber/>
			<emailAddress/>
			<additionalInformation/>
		</picsContactPerson>
	</implementationIdentification>

	<globalStatementOfConformance>
		<specVersion name="ZigBee Home Automation" version="053520r29" mandatory="true">TRUE</specVersion>
	</globalStatementOfConformance>

	<picsProforma>
		<zigBeeDeviceTypes>
			<type>
				<name>coordinator</name>
				<description>Is this device capable of acting as a ZigBee coordinator?</description>
				<supported>TRUE</supported>
				<profileItem>
					<name>Join Mode</name>
					<description>Does the device support a method for the user to put the device in join mode?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
				<profileItem>
					<name>Network Form</name>
					<description>Does the device support a method for the user to use the device to form a network?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
				<profileItem>
					<name>Permit Join</name>
					<description>Does the device support a method for allowing others to join the network?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
			</type>
			<type>
				<name>router</name>
				<description>Is this device capable of acting as a ZigBee router?</description>
				<supported>TRUE</supported>
				<profileItem>
					<name>Join Mode</name>
					<description>Does the device support a method for the user to put the device in join mode?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
				<profileItem>
					<name>Permit Join</name>
					<description>Does the device support a method for allowing others to join the network?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
			</type>
			<type>
				<name>end device</name>
				<description>Is this a ZigBee end device?</description>
				<supported>FALSE</supported>
				<profileItem>
					<name>Join Mode</name>
					<description>Does the device support a method for the user to put the device in join mode?</description>
					<mandatory>true</mandatory>
				</profileItem>
				<profileItem>
					<name>Polling Rate</name>
					<description>Does the device adhere to the polling rate specifications given in 053520r29</description>
					<mandatory>true</mandatory>
					<supported>FALSE</supported>
				</profileItem>
			</type>
		</zigBeeDeviceTypes>

		<stackProfile>
			<profileItem>
				<name>ZigBee Stack Profile</name>
				<mandatory>true</mandatory>
				<description>Is the device built on a ZigBee Compliant Platform certified for ZigBee or ZigBee PRO stack profile 080006r05?</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>Binding Table Size</name>
				<description>Does the device implement source binding with a binding table whose number of available entries is greater than or equal to the number of supported clusters that may initiate normal operational transactions. It should be noted that operational transactions are not one time transactions or commissioning transactions. Operational transactions are those that are used to perform the device function, such attribute reporting or actuation commands  (e.g. On, Off, Toggle, etc).</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>Link Keys</name>
				<description>Does the device support Trust Center Link Keys including the Default Trust Center Link Key?</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>APS Layer Multicast (CCB 1773)</name>
				<description>Does the device use only APS layer multicast for multicast messages?</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>Network Use Multicast (CCB 1773)</name>
				<description>Does the device have the stack primitive nwkUseMulticast set to FALSE?</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
		</stackProfile>

		<HAProfile>
			<profileItem>
				<name>Reset to Factory Defaults</name>
				<description>Does the device support a method for allowing a user to restore factory settings?</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>Reporting generation</name>
				<description>Does the device have attributes that are reportable?</description>
				<mandatory>false</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>Default Reporting Configuration</name>
				<description>Does the device have a default reporting configuration for each reportable attribute</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
			<profileItem>
				<name>Read Reporting Configuration</name>
				<description>Does the device support configuring and  reading a report configuration for all reportable attributes?</description>
				<mandatory>true</mandatory>
				<supported>TRUE</supported>
			</profileItem>
		</HAProfile>

		<ZDPCommands>
			<command code="0x8000" name="NWK_addr_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8001" name="IEEE_addr_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8002" name="Node_Desc_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8003" name="Power_Desc_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8004" name="Simple_Desc_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8005" name="Active_EP_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8006" name="Match_Desc_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8013" name="Device_annce" source="either" mandatory="true">TRUE</command>
			<command code="0x8021" name="Bind_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8022" name="Unbind_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8031" name="Mgmt_Lqi_rsp" source="either" mandatory="true">TRUE</command>
			<command code="0x8033" name="Mgmt_Bind_rsp" source="either" mandatory="true">TRUE</command>
		</ZDPCommands>

		<ZCLGlobalCommands>
			<command code="0x01" name="ReadAttributesResponse" source="either" mandatory="true">TRUE</command>
			<command code="0x04" name="WriteAttributesResponse" source="either" mandatory="true">TRUE</command>
			<command code="0x07" name="ConfigureReportingResponse" source="either" mandatory="true">TRUE</command>
			<command code="0x09" name="ReadReportingConfigurationResponse" source="either" mandatory="true">TRUE</command>
			<command code="0x0B" name="DefaultResponse" source="either" mandatory="true">TRUE</command>
			<command code="0x0D" name="DiscoverAttributesResponse" source="either" mandatory="true">TRUE</command>
			<command code="0x10" name="WriteAttributesStructuredResponse" source="either" mandatory="false">TRUE</command>
			<command code="0x12" name="DiscoverCommandsReceivedResponse" source="either" mandatory="false">TRUE</command>
			<command code="0x14" name="DiscoverCommandsGeneratedResponse" source="either" mandatory="false">TRUE</command>
			<command code="0x16" name="DiscoverAttributesExtendedResponse" source="either" mandatory="false">TRUE</command>
		</ZCLGlobalCommands>

		<HADeviceTypes>
			<deviceType>
				<name>HA-onoffoutput</name>
				<domain>HA</domain>
				<typeName>HA On/Off Output</typeName>
				<profileId>0x0104</profileId>
				<deviceId>0x0002</deviceId>
				<supported>TRUE</supported>
				<commissioning>
					<type name="ezMode" role="initiator" mandatory="false">TRUE</type>
					<type name="ezMode" role="target" mandatory="true">TRUE</type>
				</commissioning>
				<clusters>
					<include name="Basic" source="server" mandatory="true">TRUE</include>
					<include name="Identify" source="server" mandatory="true">TRUE</include>
					<include name="Power Configuration" source="server" mandatory="false">FALSE</include>
					<include name="Device Temperature Configuration" source="server" mandatory="false">FALSE</include>
					<include name="Alarms" source="server" mandatory="false">FALSE</include>
					<include name="Poll Control" source="server" mandatory="false">FALSE</include>
					<include name="Electrical Measurement" source="server" mandatory="false">FALSE</include>
					<include name="Time" source="client" mandatory="false">FALSE</include>
					<include name="Over the Air Bootloading Cluster" source="client" mandatory="false">TRUE</include>
					<include name="Partition" source="client" mandatory="false">FALSE</include>
					<include name="Partition" source="server" mandatory="false">FALSE</include>
					<include name="On/Off" source="server" mandatory="true">TRUE</include>
					<include name="Scenes" source="server" mandatory="true">TRUE</include>
					<include name="Groups" source="server" mandatory="true">TRUE</include>
					<include name="Identify" source="client" mandatory="true">TRUE</include>
				</clusters>
			</deviceType>
		</HADeviceTypes>

		<HAClusters>
			<cluster>
				<name>Basic</name>
				<code>0x0000</code>
				<define>BASIC_CLUSTER</define>
				<attribute source="server" code="0x0000" define="VERSION" mandatory="true" name="ZCL version">TRUE</attribute>
				<attribute source="server" code="0x0001" define="APPLICATION_VERSION" mandatory="false" name="application version">TRUE</attribute>
				<attribute source="server" code="0x0002" define="STACK_VERSION" mandatory="false" name="stack version">TRUE</attribute>
				<attribute source="server" code="0x0003" define="HW_VERSION" mandatory="false" name="hardware version">TRUE</attribute>
				<attribute source="server" code="0x0004" define="MANUFACTURER_NAME" mandatory="false" name="manufacturer name">TRUE</attribute>
				<attribute source="server" code="0x0005" define="MODEL_IDENTIFIER" mandatory="false" name="model identifier">TRUE</attribute>
				<attribute source="server" code="0x0006" define="DATE_CODE" mandatory="false" name="date code">TRUE</attribute>
				<attribute source="server" code="0x0007" define="POWER_SOURCE" mandatory="true" name="power source">TRUE</attribute>
				<attribute source="server" code="0x0008" define="APPLICATION_PROFILE_VERSION" mandatory="false" name="application profile version">FALSE</attribute>
				<attribute source="server" code="0x0010" define="LOCATION_DESCRIPTION" mandatory="false" name="location description">FALSE</attribute>
				<attribute source="server" code="0x0011" define="PHYSICAL_ENVIRONMENT" mandatory="false" name="physical environment">FALSE</attribute>
				<attribute source="server" code="0x0012" define="DEVICE_ENABLED" mandatory="false" name="device enabled">FALSE</attribute>
				<attribute source="server" code="0x0013" define="ALARM_MASK" mandatory="false" name="alarm mask">FALSE</attribute>
				<attribute source="server" code="0x0014" define="DISABLE_LOCAL_CONFIG" mandatory="false" name="disable local config">FALSE</attribute>
				<command receivedBy="server" code="0x00" name="ResetToFactoryDefaults" mandatory="false">TRUE</command>
			</cluster>

			<cluster>
				<name>Identify</name>
				<code>0x0003</code>
				<define>IDENTIFY_CLUSTER</define>
				<attribute source="server" code="0x0000" define="IDENTIFY_TIME" mandatory="true" name="identify time">TRUE</attribute>
				<attribute source="server" code="0x0001" define="COMMISSION_STATE" mandatory="false" name="commission state">TRUE</attribute>
				<command receivedBy="server" code="0x00" name="Identify" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x01" name="IdentifyQuery" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x00" name="IdentifyQueryResponse" mandatory="true">TRUE</command>
				
			</cluster>

			<cluster>
				<name>Groups</name>
				<code>0x0004</code>
				<define>GROUPS_CLUSTER</define>
				<profileItem>
					<name>Groups Table Size</name>
					<description>Does the device support at least 8 entries in the group table?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
				<attribute source="server" code="0x0000" define="GROUP_NAME_SUPPORT" mandatory="true" name="name support">TRUE</attribute>
				<command receivedBy="server" code="0x00" name="AddGroup" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x01" name="ViewGroup" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x02" name="GetGroupMembership" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x03" name="RemoveGroup" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x04" name="RemoveAllGroups" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x05" name="AddGroupIfIdentifying" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x00" name="AddGroupResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x01" name="ViewGroupResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x02" name="GetGroupMembershipResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x03" name="RemoveGroupResponse" mandatory="true">TRUE</command>
			</cluster>

			<cluster>
				<name>Scenes</name>
				<code>0x0005</code>
				<define>SCENES_CLUSTER</define>
				<profileItem>
					<name>Scenes Table Size</name>
					<description>Does the device support at least 16 entries in the scenes table?</description>
					<mandatory>true</mandatory>
					<supported>TRUE</supported>
				</profileItem>
				<attribute source="server" code="0x0000" define="SCENE_COUNT" mandatory="true" name="scene count">TRUE</attribute>
				<attribute source="server" code="0x0001" define="CURRENT_SCENE" mandatory="true" name="current scene">TRUE</attribute>
				<attribute source="server" code="0x0002" define="CURRENT_GROUP" mandatory="true" name="current group">TRUE</attribute>
				<attribute source="server" code="0x0003" define="SCENE_VALID" mandatory="true" name="scene valid">TRUE</attribute>
				<attribute source="server" code="0x0004" define="SCENE_NAME_SUPPORT" mandatory="true" name="name support">TRUE</attribute>
				<attribute source="server" code="0x0005" define="LAST_CONFIGURED_BY" mandatory="false" name="last configured by">FALSE</attribute>
				<command receivedBy="server" code="0x00" name="AddScene" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x01" name="ViewScene" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x02" name="RemoveScene" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x03" name="RemoveAllScenes" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x04" name="StoreScene" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x05" name="RecallScene" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x06" name="GetSceneMembership" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x00" name="AddSceneResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x01" name="ViewSceneResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x02" name="RemoveSceneResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x03" name="RemoveAllScenesResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x04" name="StoreSceneResponse" mandatory="true">TRUE</command>
				<command receivedBy="client" code="0x06" name="GetSceneMembershipResponse" mandatory="true">TRUE</command>
			</cluster>

			<cluster>
				<name>On/off</name>
				<code>0x0006</code>
				<define>ON_OFF_CLUSTER</define>
				<attribute source="server" code="0x0000" define="ON_OFF" mandatory="true" name="on/off">TRUE</attribute>
				<command receivedBy="server" code="0x00" name="Off" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x01" name="On" mandatory="true">TRUE</command>
				<command receivedBy="server" code="0x02" name="Toggle" mandatory="true">TRUE</command>
			</cluster>

			<cluster>
				<name>Over the Air Bootloading</name>
				<code>0x0019</code>
				<define>OTA_BOOTLOAD_CLUSTER</define>
				<attribute side="client" type="IEEE_ADDRESS" code="0x0000" define="UPGRADE_SERVER_ID" name="OTA Upgrade Server ID">TRUE</attribute>
				<attribute side="client" type="INT32U" code="0x0001" define="FILE_OFFSET" name="Offset (address) into the file">TRUE</attribute>
				<attribute side="client" type="INT32U" code="0x0002" define="CURRENT_FILE_VERSION" name="OTA Current File Version">TRUE</attribute>
				<attribute side="client" type="INT16U" code="0x0003" define="CURRENT_ZIGBEE_STACK_VERSION" name="OTA Current ZigBee Stack Version">TRUE</attribute>
				<attribute side="client" type="INT32U" code="0x0004" define="DOWNLOADED_FILE_VERSION" name="OTA Downloaded File Version">TRUE</attribute>
				<attribute side="client" type="INT16U" code="0x0005" define="DOWNLOADED_ZIGBEE_STACK_VERSION" name="OTA Downloaded ZigBee Stack Version">TRUE</attribute>
				<attribute side="client" type="ENUM8" code="0x0006" define="IMAGE_UPGRADE_STATUS" name="OTA Upgrade Status">TRUE</attribute>
				<attribute side="client" type="INT16U" code="0x0007" define="MANUFACTURER_ID" name="Manufacturer ID">TRUE</attribute>
				<attribute side="client" type="INT16U" code="0x0008" define="IMAGE_TYPE_ID" name="Image Type ID">TRUE</attribute>
				<attribute side="client" type="INT16U" code="0x0009" define="MINIMUM_BLOCK_REQUEST_PERIOD" name="Minimum Block Request Period">FALSE</attribute>
				<command code="0x0" name="ImageNotify" source="server">TRUE</command>
				<command code="0x1" name="QueryNextImageRequest" source="client">TRUE</command>
				<command code="0x2" name="QueryNextImageResponse" source="server">TRUE</command>
				<command code="0x3" name="ImageBlockRequest" source="client">TRUE</command>
				<command code="0x4" name="ImagePageRequest" source="client">FALSE</command>
				<command code="0x5" name="ImageBlockResponse" source="server">TRUE</command>
				<command code="0x6" name="UpgradeEndRequest" source="client">TRUE</command>
				<command code="0x7" name="UpgradeEndResponse" source="server">TRUE</command>
				<command code="0x8" name="QuerySpecificFileRequest" source="client">FALSE</command>
				<command code="0x9" name="QuerySpecificFileResponse" source="server">FALSE</command>
			</cluster>
		</HAClusters>
	</picsProforma>
</homeAutomationPICs>