Implemenation Under Test Identification
Scene Scenario Switch (WSS-4E-ZBS)
1.0
System Under Test Identification
Z-Stack Home
1.0
1.0
Z-Stack
Product Supplier
Climax Technology Co., Ltd.
No.258, Hsin Hu 2nd Road, Taipei 114, Taiwan
+886-2-27940001#254
+886-2-27926618
monicalin@climax.com.tw
Client
PICS Contact Person
Monica Lin
No.258, Hsin Hu 2nd Road, Taipei 114, Taiwan
+886-2-27940001#254
+886-2-27926618
monicalin@climax.com.tw
TRUE
end device
Is this a ZigBee end device?
Join Mode
Does the device support a method for the user to put the device in join mode?
true
Polling Rate
Does the device adhere to the polling rate specifications given in 053520r29
true
ZigBee Stack Profile
true
Is the device built on a ZigBee Compliant Platform certified for ZigBee or ZigBee PRO stack profile 080006r05?
true
TRUE
Binding Table Size
Does the device implement source binding with a binding table whose number of available entries is greater than or equal to the number of supported clusters that may initiate normal operational transactions. It should be noted that operational transactions are not one time transactions or commissioning transactions. Operational transactions are those that are used to perform the device function, such attribute reporting or actuation commands (e.g. On, Off, Toggle, etc).
true
TRUE
Link Keys
Does the device support Trust Center Link Keys including the Default Trust Center Link Key?
true
TRUE
APS Layer Multicast (CCB 1773)
Does the device use only APS layer multicast for multicast messages?
true
TRUE
Network Use Multicast (CCB 1773)
Does the device have the stack primitive nwkUseMulticast set to FALSE?
true
TRUE
Cluster Library PICs
Does the device support the ZigBee Cluster Library PICS as defined in 064118r08
true
TRUE
Reset to Factory Defaults
Does the device support a method for allowing a user to restore factory settings?
true
TRUE
Reporting generation
Does the device have attributes that are reportable?
false
TRUE
Default Reporting Configuration
Does the device have a default reporting configuration for each reportable attribute
false
TRUE
Read Reporting Configuration
Does the device support configuring and reading a report configuration for all reportable attributes?
false
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
HA-sceneselector
HA
HA Scene Selector
0x0104
0x0004
TRUE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
Basic
0x0000
BASIC_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Identify
0x0003
IDENTIFY_CLUSTER
TRUE
TRUE
TRUE
TRUE
Groups
0x0004
GROUPS_CLUSTER
Groups Table Size
Does the device support at least 8 entries in the group table?
true
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Scenes
0x0005
SCENES_CLUSTER
Scenes Table Size
Does the device support at least 16 entries in the scenes table?
true
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE