Implemenation Under Test Identification
Salus Embedded Door Sensor
System Under Test Identification
SS881ZB
201607070
1
Product Supplier
Computime, Ltd.
9/F Tower One, Lippo Centre, 89 Queensway, Hong Kong
852-2260-0300
wlha@computime.com
Product Supplier
Salus Controls, Inc.
1750 Montgomery Street, 1st Floor, San Franscisco, CA 94111
(415) 881 7436
shen@salusinc.com
PICS Contact Person
WL HA
9/F Tower One, Lippo Centre, 89 Queensway, Hong Kong
+852 22600300
wlha@computime.com
end device
Is this a ZigBee end device?
TRUE
Join Mode
Does the device support a method for the user to put the device in join mode?
true
TRUE
Polling Rate
Does the device adhere to the polling rate specifications given in 053520r29
true
TRUE
ZigBee Stack Profile
true
Is the device built on a ZigBee Compliant Platform certified for ZigBee or ZigBee PRO stack profile 080006r05?
true
TRUE
Binding Table Size
Does the device implement source binding with a binding table whose number of available entries is greater than or equal to the number of supported clusters that may initiate normal operational transactions. It should be noted that operational transactions are not one time transactions or commissioning transactions. Operational transactions are those that are used to perform the device function, such attribute reporting or actuation commands (e.g. On, Off, Toggle, etc).
true
TRUE
Link Keys
Does the device support Trust Center Link Keys including the Default Trust Center Link Key?
true
TRUE
APS Layer Multicast (CCB 1773)
Does the device use only APS layer multicast for multicast messages?
true
TRUE
Network Use Multicast (CCB 1773)
Does the device have the stack primitive nwkUseMulticast set to FALSE?
true
TRUE
Cluster Library PICs
Does the device support the ZigBee Cluster Library PICS as defined in 064118r08
true
TRUE
Reset to Factory Defaults
Does the device support a method for allowing a user to restore factory settings?
true
TRUE
Reporting generation
Does the device have attributes that are reportable?
false
TRUE
Default Reporting Configuration
Does the device have a default reporting configuration for each reportable attribute
false
FALSE
Read Reporting Configuration
Does the device support configuring and reading a report configuration for all reportable attributes?
false
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
HA-iaszone
HA
HA IAS Zone
0x0104
0x0402
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Basic
0x0000
BASIC_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Power Configuration
0x0001
POWER_CONFIG_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Identify
0x0003
IDENTIFY_CLUSTER
TRUE
TRUE
TRUE
TRUE
Poll Control
0x0020
POLL_CONTROL_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Temperature Measurement
0x0402
TEMP_MEASUREMENT_CLUSTER
TRUE
TRUE
TRUE
TRUE
IAS Zone
0x0500
IAS_ZONE_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Diagnostics
0x0B05
DIAGNOSTICS_CLUSTER
TRUE
TRUE
TRUE
Commissioning
0x0015
COMMISSIONING_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Over the Air Bootloading
0x0019
OTA_BOOTLOAD_CLUSTER
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE