Implemenation Under Test Identification
LS2025
V300R017C00
System Under Test Identification
V300R017C00
A47.A
Linux version 3.10.53-HULK2
Product Supplier
Huawei Technologies Co., Ltd.
Administration Building,Huawei Technologies Co., Ltd. Bantian,Long gang District,Shenzhen,Guangdong 518129 P.R.C.
+86-027-13006115129
liuzhengwen@huawei.com
Client
Liu Zhengwen
A7-20, Optical Valley Software Park,Guanshan Road,Wuhan, Hubei 430074 P.R.C.
+86-027-13006115129
liuzhengwen@huawei.com
PICS Contact Person
Liu Zhengwen
A7-20, Optical Valley Software Park,Guanshan Road,Wuhan, Hubei 430074 P.R.C.
+86-027-13006115129
liuzhengwen@huawei.com
TRUE
coordinator
Is this device capable of acting as a ZigBee coordinator?
TRUE
Join Mode
Does the device support a method for the user to put the device in join mode?
true
TRUE
Network Form
Does the device support a method for the user to use the device to form a network?
true
TRUE
Permit Join
Does the device support a method for allowing others to join the network?
true
TRUE
ZigBee Stack Profile
true
Is the device built on a ZigBee Compliant Platform certified for ZigBee or ZigBee PRO stack profile 080006r05?
true
TRUE
Binding Table Size
Does the device implement source binding with a binding table whose number of available entries is greater than or equal to the number of supported clusters that may initiate normal operational transactions. It should be noted that operational transactions are not one time transactions or commissioning transactions. Operational transactions are those that are used to perform the device function, such attribute reporting or actuation commands (e.g. On, Off, Toggle, etc).
true
TRUE
Link Keys
Does the device support Trust Center Link Keys including the Default Trust Center Link Key?
true
TRUE
APS Layer Multicast (CCB 1773)
Does the device use only APS layer multicast for multicast messages?
true
TRUE
Network Use Multicast (CCB 1773)
Does the device have the stack primitive nwkUseMulticast set to FALSE?
true
TRUE
Cluster Library PICs
Does the device support the ZigBee Cluster Library PICS as defined in 064118r08
true
TRUE
Reset to Factory Defaults
Does the device support a method for allowing a user to restore factory settings?
true
TRUE
Reporting generation
Does the device have attributes that are reportable?
false
TRUE
Default Reporting Configuration
Does the device have a default reporting configuration for each reportable attribute
false
TRUE
Read Reporting Configuration
Does the device support configuring and reading a report configuration for all reportable attributes?
false
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
HA-combinedinterface
HA
HA Combined Interface
0x0104
0x0007
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
Basic
0x0000
BASIC_CLUSTER
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
Identify
0x0003
IDENTIFY_CLUSTER
TRUE
FALSE
TRUE
TRUE
TRUE
Groups
0x0004
GROUPS_CLUSTER
Groups Table Size
Does the device support at least 8 entries in the group table?
true
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
Scenes
0x0005
SCENES_CLUSTER
Scenes Table Size
Does the device support at least 16 entries in the scenes table?
true
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
On/off
0x0006
ON_OFF_CLUSTER
FALSE
FALSE
FALSE
FALSE
Temperature Measurement
0x0402
TEMP_MEASUREMENT_CLUSTER
FALSE
FALSE
FALSE
FALSE
Relative Humidity Measurement
0x0405
RELATIVE_HUMIDITY_MEASUREMENT_CLUSTER
FALSE
FALSE
FALSE
FALSE
IAS Zone
0x0500
IAS_ZONE_CLUSTER
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
IAS WD
0x0502
IAS_WD_CLUSTER
FALSE
FALSE
FALSE