Implemenation Under Test Identification RapidHA Combined Interface 0.9.2 System Under Test Identification 0.9.2 Z357PA30-USB Product Supplier MMB Networks
25 Prince Arthur Ave
416-636-3145 416-636-3145 gusupport@mmbnetworks.com
Client MMB Networks
25 Prince Arthur Ave
416-636-3145 gusupport@mmbnetworks.com
PICS Contact Person Eugene Peng
25 Prince Arthur Ave
416-636-3145 gusupport@mmbnetworks.com
TRUE coordinator Is this device capable of acting as a ZigBee coordinator? TRUE Network Form Does the device support a method for the user to use the device to form a network? true TRUE Permit Join Does the device support a method for allowing others to join the network? true TRUE ZigBee Stack Profile true Is the device built on a ZigBee Compliant Platform certified for ZigBee or ZigBee PRO stack profile 080006r05? true TRUE Binding Table Size Does the device implement source binding with a binding table whose number of available entries is greater than or equal to the number of supported clusters that may initiate normal operational transactions. It should be noted that operational transactions are not one time transactions or commissioning transactions. Operational transactions are those that are used to perform the device function, such attribute reporting or actuation commands (e.g. On, Off, Toggle, etc). true TRUE Link Keys Does the device support Trust Center Link Keys including the Default Trust Center Link Key? true TRUE APS Layer Multicast (CCB 1773) Does the device use only APS layer multicast for multicast messages? true TRUE Network Use Multicast (CCB 1773) Does the device have the stack primitive nwkUseMulticast set to FALSE? true TRUE Cluster Library PICs Does the device support the ZigBee Cluster Library PICS as defined in 064118r08 true TRUE Reset to Factory Defaults Does the device support a method for allowing a user to restore factory settings? true TRUE Reporting generation Does the device have attributes that are reportable? false FALSE Default Reporting Configuration Does the device have a default reporting configuration for each reportable attribute false FALSE Read Reporting Configuration Does the device support configuring and reading a report configuration for all reportable attributes? false FALSE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE HA-combinedinterface HA HA Combined Interface Coordinator 0x0104 0x0007 TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE TRUE TRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE Basic 0x0000 BASIC_CLUSTER TRUE FALSE FALSE FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE FALSE Identify 0x0003 IDENTIFY_CLUSTER TRUE TRUE TRUE TRUE TRUE Time General 0x000A TIME_CLUSTER TRUE TRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE